MARSEN
Environment
Product
ULLAGE TEMPERATURE INTERFACE DETECTOR
UTL-300
- GENERAL INFORMATION
- Ship(tanker) must be equipped with interface detector that approved by the government.
- Compared to fixed type tank level gauging system, portable type tank level gauging System has many advantages, it is very useful to work of tank level gauging on the deck.
- In case the Oil/Water Interface Detector is required for the chemical carrier installed in slop tank and is also loading oil products, The IMO MARPOL 1973/78 requirement is that slop tank must be provided to retain the slop tank generated by tank washing, Oil residues and dirty ballast residues in order to preserve the sea from pollution by oil.
- Furthermore, IMO MARPOL Regulation 15,(3)(b) : Effective Oil/ Water Interface Detectors approved by the administration shall be provided for a rapid and accurate determination of Oil/Water Interface in slop tank and shall be available for use in other tanks where the separation of oil and water is effective and from which it is intended to discharge effluent direct to the sea.
- UTL–300 is satisfied the requirements of MARPOL 1973/78, Regulation 15(3)(b) and Resolution MEPC.5(XIII) Annex 4.
FEATURE & ADVANTAGE
- High accuracy and responsibility
- Possible to protect the operator
- Prevent the environmental pollution
- Easy operation and maintenance
APPLICATION
All kinds of oil & chemical tankers
OPERATION PRINCIPLE & SYSTEM COMPOSITION
ULLAGE TEMPERATURE INTERFACE DETECTOR is necessary for cargo tanker and it is designed for measuring the ullage level, the oil-water interface level,
the temperature and sampling the cargo.
UTL–300 detects a change of the impedance by using ultrasonic technology and measures the difference of voltage according to the conductivity of the water.
In addition, it can measure the temperature by the output voltage of the built-in semiconductor element.
TECHNICAL SPECIFICATION
SUBJECT | SPECIFICATION | |
---|---|---|
UTL - 300 - ULLAGE TEMPERATURE INTERFACE DETECTOR |
ACCURACY | ±2mm |
TAPE GRADUATION | Metric | |
TAPE RESOLUTION | 1mm | |
TAPE LENGTH | 15m / 30m / 37m | |
MEASURING TEMP. RANGE | -10°C~90°C | |
EX GRADE | Ex ia IIC T4 |
COMPONENTS / OUTLINE